Boss / Projects / TekLAB
 
  
Please use this configurator to determine your requirements, then cut and paste the part # and full description into an email to your local manufacturer sales rep or Berk-Tek inside sales person to request pricing and lead time information.
Additional configurations are available. Contact Customer Service at 1-800-BERKTEK (1-800-237-5835)
Enter an existing part:    

or build a new part by configuring your assembly below:
Product Sub Category:
Cable Type:
    Click here for more detail
Ribbon Interconnect
Adventum
Move cursor over text below to view cable image.
  • Adventum (6-144 Fiber, Indoor/Outdoor Loose Tube, Dry Water Block, Plenum or Riser Optical Cable). For higher fiber counts contact 1-800-BERK-TEK.
  • Adventum with ArmorTek (6-144 Fiber, Indoor/Outdoor Loose Tube, Dry Water Block, Plenum or Riser Optical Cable with Aluminum Interlocking Armor). For higher fiber counts contact 1-800-BERK-TEK.
  • Adventum Tight Buffer (1-2 Tight Buffered Fibers, 900 micron, Indoor/Outdoor Loose Tube, Dry Water Block, Plenum or Riser Optical Cable)
  • Aramid Connect Plenum (Aramid Connect Plenum Description). For higher fiber counts contact 1-800-BERK-TEK.
  • Micro Data Center (4-144 Fiber MDP, Loose Tube Plenum, Indoor only, for Data Center High Density Installations)
  • Micro Data Center with ArmorTek (4-144 Fiber MDPK, Loose Tube Plenum with Aluminum Interlocking Armor, Indoor only, for Data Center High Density Installations)
  • Premises Distribution (6-144 Tight Buffered Fibers, 900 micron, Indoor Plenum or Riser Optical Cable)
  • Premises Distribution with ArmorTek (6-144 Tight Buffered Fibers, 900 micron, Indoor Plenum or Riser Optical Cable with Aluminum Interlocking Armor)
  • Ribbon Interconnect (12 Fiber, Indoor Plenum Optical Cable)
  • Interconnect Round (2-4 Tight Buffered Fibers, 900 micron, Indoor Plenum or Riser Optical Cable)
Cable Flame Rating: Plenum Riser
Fiber Strands Count:
Multimode Count:     Singlemode Count: 
Fiber Type:
     Click here for more detail
  Outside End - Pulling End
Default polarity method used is Method A (Straight Thru). Available polarity methods are listed in the “Polarity” section below.
Break-Out Side A: 900 Micron    2.0mm Furcation   None (Standard Breakout is 39")
Custom Requirement Side A:   Click this box to enter custom breakout length, special jacket color, custom labeling, etc.
  Please Specify Special Requirements
Key Side A: Standard    Secured Red     Secured Yellow     Secured Green     Secured Blue
Connector Side B: Inside End
Default polarity method used is Method A (Straight Thru). Available polarity methods are listed in the “Polarity” section below.
Break-Out Side B: 900 Micron    2.0mm Furcation      None (Standard Breakout is 39")
Custom Requirement Side B:   Click this box to enter custom breakout length, special jacket color, custom labeling, etc.
    Please Specify Special Requirements
Key Side B: Standard    Secured Red     Secured Yellow     Secured Green     Secured Blue
  When creating an assembly with connectors on 1 side only, it is recommended that the connectors be on the inside end (Side B).
Ground Wire: Side B Only
Pulling Eye Option: No    Outside End - Pulling End    Both Ends
For maximum protection of the terminated inside cable end,
a pulling-eye on BOTH cable ends should be specified
Contact Inside Sales for Pulling Eye Options
Pulling Eye Type: Std w/ Crush Resistant Tube
Standard Pulling eye requires min. 3" ID duct (PE has a OD 2" nom)
Polarity     Click here for more detail
Length Type:
Enter Length:    Meters
Enter Multi-Lengths: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10.
Multi-Length Qtys: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10.
Competitor Price: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10.
Units: Feet Meters
Order Quantity:      
Berk-Tek Part #:
Berk-Tek Description:
Notes (Internal Comments):